Click here to view and discuss this page in DocCommentXchange. In the future, you will be sent there automatically.

SQL Anywhere 10.0.1 » SQL Anywhere 10 - Context-Sensitive Help » MobiLink Plug-in Model Mode Help » MobiLink Model mode wizards

Deploy Synchronization Model wizard: Verbosity for MobiLink Server page Next Page

Deploy Synchronization Model wizard: Options for MobiLink Server page


This page allows you to set options for the MobiLink server.

This page has the following components:

What name do you want to give the MobiLink server?    Type the name of the MobiLink server.

Additional MobiLink server command-line options    Type any additional MobiLink server options. See MobiLink Server Options.

The following table lists the options you can specify.

Option

Description

@data

Read in options from the specified environment variable or configuration file. See @data option.

-a

Disable automatic reconnection upon synchronization error. See -a option.

-b

Trim blank padding of strings. See -b option.

-bn size

Specify the maximum number of bytes to consider when comparing BLOBs for conflict detection. See -bn option.

-c "keyword=value; ..."

Supply ODBC database connection parameters for your consolidated database. See -c option.

-cm size

Specify the server memory cache size. See -cm option.

-cn connections

Set the maximum number of simultaneous connections with the consolidated database server. See -cn option.

-cr count

Set the maximum number of database connection retries. See -cr option.

-ct connection-timeout

Set the length of time a connection may be unused before it is timed out. See -ct option.

-dl

Display all log messages on the console. See -dl option.

-ds size

Specify the maximum amount of data that can be stored for use in all restartable downloads. See -ds option.

-dsd

Disable snapshot isolation, which is the default download isolation level for SQL Anywhere and Microsoft SQL Server consolidated databases. See -dsd option.

-dt

Detect transactions only within the current database. See -dt option.

-e filename

Store remote error logs sent into the named file. See -e option.

-esu

Use snapshot isolation for uploads. See -esu option.

-et filename

Store remote error logs sent into the named file, but delete the contents first if the file exists. See -et option.

-f

Assume synchronization scripts do not change. See -f option.

-fips

Forces all secure MobiLink streams to be FIPS-compliant. See -fips option.

-fr

If table data scripts are missing, synchronization will not abort, but just issue a warning. See -fr option.

-ftr path

Creates a location for files that are to be used by the mlfiletransfer utility. See -ftr option.

-m [filename]

Enables QAnywhere messaging. See -m option.

-nc connectionsSets maximum number of concurrent connections. See -nc option.

-notifier

Starts a Notifier for server-initiated synchronization. See -notifier option.

-o logfile

Log messages to a file. See -o option.

-on size

Set maximum size for log file. See -on option.

-oq

Prevent the popup dialog on startup error. See -oq option.

-os size

Maximum size of output file. See -os option.

-ot logfile

Log messages to a file, but delete its contents first. See -ot option.

-q

Minimize the synchronization server window. See -q option.

-r retries

Retry deadlocked uploads at most this many times. See -r option.

-rd delay

Set maximum delay, in seconds, before retrying a deadlocked transaction. See -rd option.

-s count

Specify the maximum number of rows to be fetched or sent at once. See -s option.

-sl dnet script-options

Set the .NET CLR options and force loading of the virtual machine on startup. See -sl dnet option.

-sl java script-options

Set the Java virtual machine options and force loading of the virtual machine on startup. See -sl java option.

-sm numberSet the maximum number of synchronizations that can be actively worked on. See -sm option.

-ud

On UNIX platforms, run as a daemon. See -ud option.

-ux

Opens the console. See -ux option.

-v [ levels ]

Controls the type of messages written to the log file. See -v option.

-w count

Set the number of database worker threads. See -w option.

-wu count

Set the maximum number of database worker threads permitted to process uploads concurrently. See -wu option.

-x protocol[ (network-parameters) ]

Specify the communications protocol. Optionally, specify network parameters in form parameter=value, with multiple parameters separated by semicolons. See -x option.

-xo protocol[ (network-parameters) ]

For version 8 and 9 clients, specify the communications protocol. Optionally, specify network parameters in form parameter=value, with multiple parameters separated by semicolons. See -xo option.

-zp

In the event of a timestamp conflict between the consolidated and remote database, this option allows timestamp values with a precision higher than the lowest-precision to be used for conflict detection purposes. See -zp option.

-zs name

Specify a server name. See -zs option.

-zt number

Specify the maximum number of processors used to run the MobiLink server. See -zt option.

-zu { + | - }

Controls the automatic addition of users when the authenticate_user script is undefined. See -zu option.

-zus

Causes MobiLink to invoke upload scripts for tables for which there is no upload. See -zus option.

-zw 1,...5

Controls which levels of warning message to display. See -zw option.

-zwd code

Disables specific warning codes. See -zwd option.

-zwe code

Enables specific warning codes. See -zwe option.

Where do you want to save the command file that will be generated for starting the MobiLink server?    Type the location where you want the command file saved, or click Browse to select the file.

See also